CYLINDRICAL MOUNTS
to 28.5 lbs. |
| www.vibrationmounts.com • Phone: 516.328.3662 • FAX: 516.328.3365 |
   |
|
| V100 page 1-7 |
|
 |
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Natural Rubber
FOR COMPRESSION LOADS OF:
22 to 28.5 Pounds (10 to 12.9 kgf)
FOR SHEAR LOADS OF:
8.4 to 11.9 Pounds (3.8 to 5.4 kgf)
|

NOTE: Dimensions in ( ) are in mm. |
| CAD |
Catalog
Number |
Mode |
Max.
Load
lb. (kgf) |
Forcing Frequency in Cycles per Minute |
| 1500 |
1750 |
2000 |
2250 |
2500 |
3000 |
3600 |
| Minimum Load for 81% Isolation lb. (kgf) |
 |
V10Z 2-307A |
Compression
|
2.0 (10) |
- |
- |
- |
21.5 (9.8) |
16.5 (7.5) |
10.5 (4.8) |
6.5 (2.9) |
| Shear |
8.4 (3.8) |
6.2 (2.8) |
4.7 (2.1) |
3.7 (1.7) |
3.0 (1.4) |
2.4 (1.09) |
2.5 (1.13) |
* |
 |
V10Z 2-307B |
Compression
|
28.5 (12.9) |
- |
- |
- |
- |
25.5 (11.6) |
17.0 (7.7) |
12.0 (5.4) |
| Shear |
11.9 (5.4) |
9.9 (4.5) |
7.3 (3.3) |
5.6 (2.5) |
4.4 (2) |
3.6 (1.6) |
* |
* |
|
*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY. |
|
LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads.
NOTE:
Maximum unthreaded portion of stud does not exceed 1/16" (1.59 mm).
|
|
|
| |