6-10
www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365
V10Z 5-110C
16
(0.29)
Forcing Frequency in Cycles per Minute
20
(0.36)
1500
1800
26.5
(0.47)
Channel Mounts To 52 lbs./in.
2-3/32
(53.2)
A
B
7/64
(2.8)
3/4
(19.1)
1-7/8
(47.6)
1-3/16
(30.2)
4-1/4
(108)
INSTALLATION INFORMATION
HOLES DRILLED AT ASSEMBLY
BY CUSTOMER, AS REQUIRED
MFG. HOLE
30
(762)
Style 110 for Suspended Loads
Spacers and Mounting Hardware NOT Provided
DEFLECTION (in.)
LOAD
SUPPORT
x
70
60
50
40
30
20
10
0
0.05
0.10
0.15
0.20
0.25
LOAD DEFLECTION GRAPH
Deflections below the line x-x are
considered safe practice for static loads;
data above that line are useful for
calculating deflections under dynamic loads.
x
110C
(PER INCH
LENGTH)
Catalog Number
NOTE: 81% vibration absorption (usually satisfactory) will be obtained when the mount indicated is operating at the minimum load shown for each forced frequency. Better
than 81% absorption will be obtained either with a greater load (within the limits shown) for a given forced frequency, or with a higher forced frequency for a given load.
52
(0.93)
Load
Limit
lb./in.
(kgf/mm)
1200
Min. Load for 81% Isolation lb./in. (kgf/mm)
2100
2400
NOTE: Dimensions in ( ) are mm.
Dimensions
in. (mm)
1-39/64
(40.9)
3/8
(9.5)
A
B
35
(0.63)
52
(0.93)
FOR LOADS UP TO 52 lb. / in. (0.93 kgf / mm) OF LENGTH
SUPPLIED IN 30 INCH (762 mm) LENGTHS
MATERIAL: Isolator Natural Rubber
Channels Steel