2-21
www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365
102
(46.3)
75
(34)
195
(88.5)
260
(118)
360
(163.3)
335
(152)
Rectangular Mounts To 900 lbs.
Catalog NumberD
V10Z 6-530C
750
850
950
1250
1100
1500
1750
900 (408)
800
(362.9)
Maximum
Load lb. (kgf)
NOTE: 81% vibration absorption (usually satisfactory) will be obtained when the mounting indicated is operating at the minimum load shown for each forced frequency.
Better than 81% absorption will be obtained either with a greater load (within the limits shown) for a given forced frequency, or with a higher forced frequency for a
given load.
*At these forcing frequencies, lesser loads will yield 81% isolation.
DTo be discontinued when present stock is depleted.
Catalog NumberD
V10Z 6-530C
750
850
950
1250
1100
1500
1750
360 (163.3)
155
(70.3)
Maximum
Load lb. (kgf)
Compression
Shear
Forcing Frequency in Cycles per Minute
Minimum Load for 81% Isolation lb. (kgf)
Forcing Frequency in Cycles per Minute
Minimum Load for 81% Isolation lb. (kgf)
2000
2500
3000
590
(267.6)
390
(177)
270
(122.5)
2000
3000
55
(25)
*
*
2500
NOTE: Dimensions in ( ) are mm.
FOR COMPRESSION LOADS TO 900 POUNDS (408 kgf)
FOR SHEAR LOADS TO 360 POUNDS (163.3 kgf)
MATERIAL: Isolator Natural Rubber
Base Steel
LOAD DEFLECTION GRAPH
Deflection below the line x-x are considered
safe practice for static loads; data above that
line are useful for calculating deflections under
dynamic loads.
COMPRESSION
SHEAR
COMPRESSION
SHEAR
X
X
X
X
0
0.1
0.2
0.3
0.4
0.5
1200
1100
1000
900
800
700
600
500
400
300
200
100
DEFLECTION (in.)
2-1/4
(57.2)
3/8
(9.5)
3-1/8
(79.4)
4-9/16
(115.9)
1-7/16
(36.5)
3/4-10 NC-2
1/4
(6.4)
SECTION X-X
5/8 DIA.
(15.9)
3
(76.2)
1-1/2
(38.1)
3/4
(19.1)
1-1/2
(38.1)
5
(127)
6-1/2
(165.1)
3
(76.2)
X
X
1-3/4
(44.5)