1-26 www.vibrationmounts.com  Phone:  516.328.3662  Fax:  516.328.3365 V10Z  2-308A V10Z  2-308B V10Z  2-308C V10Z  2-308D 25 (11.3) 35 (15.9)   40 (18.1)   60 (27.2) 100 (45.4) 135 (61.2) 95 (43.1)   95 (43.1) 135 (61.2) 185 (83.9) 210 (95.3) Cylindrical Mounts – To 210 lbs. MATERIAL:  Fasteners – Steel, Zinc Plated            Isolator Natural Rubber Catalog Number Compression Maximum Load lb. (kgf) Forcing Frequency in Cycles per Minute Minimum Load for 81% Isolation lb. (kgf) 1150 1250 3500 2750 2000 1750 1500 FOR COMPRESSION LOADS OF 95 TO 210 POUNDS (43.1 TO 95.3 kgf) NOT RECOMMENDED FOR STATIC SHEAR LOADS 1 (25.4) 5/16-18 NC TAPPED .40 (10.2) DEEP MIN. 1-1/2 (38.1) 5/16-18 NC x 9/16 (14.3) A B C D DEFLECTION (in.) 0 0.05 0.10 0.15 0.20 0.25 0.30 50 100 150 200 250 300 350 400 COMPRESSION 450 LOAD DEFLECTION GRAPHS Deflections below the line x–x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. NOTE: Dimensions in (  ) are mm.   80 (36.3) 125 (56.7)   55 (24.9)   85 (38.6) 140 (63.5) 185 (83.9)   30 (13.6)   45 (20.4)   75   (34) 105 (47.6) 15   (6.8) 22   (10) 40 (18.1) 55 (24.9)