1-5
www.vibrationmounts.com Phone: 516.328.3662 Fax: 516.328.3365
Cylindrical Mounts To 13.3 lbs.
FOR COMPRESSION LOADS OF 4.9 TO 13.3 POUNDS (2.2 TO 6 kgf)
FOR SHEAR LOADS OF 2.7 TO 6.4 POUNDS (1.2 TO 2.9 kgf)
MATERIAL: Fasteners Steel, Zinc Plated
Isolator Natural Rubber
3/8
(9.5)
1/2
(12.7)
7/16
(11.1)
#8-32 NC (TYP)
Catalog Number
V10Z 2-302A
V10Z 2-302B
V10Z 2-302C
V10Z 2-302D
*At these forcing frequencies, lesser loads will yield less than 81% isolation.
SHEAR
A
B
C
D
x
x
x
x
x
x
DEFLECTION (in.)
0
0.05
0.10
0.15
0.20
0.25
0.30
2
4
6
8
1
3
5
7
COMPRESSION
A
B
C
D
x
x
x
x
x
x
x
x
DEFLECTION (in.)
0
0.04
0.06
0.02
0.08
0.10
0.12
2
4
6
8
10
12
14
NOTE:
Maximum unthreaded portion of
stud does not exceed 1/16 inch
(1.59 mm).
LOAD DEFLECTION GRAPHS
Deflections below the line xx
are considered safe practice for
static loads; data above that line
are useful for calculating
deflections under dynamic loads.
3.9 (1.8)
.7 (0.3)
5.3 (2.4)
1.1 (0.5)
9.8 (4.4)
1.9 (0.9)
13.1 (5.9)
2.7 (1.2)
1.0 (0.5)
1.4 (0.6)
2.5 (1.1)
3.4 (1.5)
Compression
Shear
Compression
Shear
Compression
Shear
Compression
Shear
2.0 (0.9)
*
2.9 (1.3)
.6 (0.27)
5.2 (2.4)
1.1 (0.5)
7.0 (3.2)
1.6 (0.7)
1.8 (0.8)
*
2.5 (1.1)
*
4.3 (1.9)
.9 (0.4)
5.8 (2.6)
1.4 (0.6)
4.9 (2.2)
2.7 (1.22)
6.4 (2.9)
3.6 (1.6)
10.4 (4.7)
5.6 (2.5)
13.3 (6)
6.4 (2.9)
1.0 (0.5)
*
1.5 (0.7)
*
2.6 (1.2)
.7 (0.3)
4.2 (1.9)
1.0 (0.45)
2.6 (1.2)
1.7 (0.8)
2.6 (1.2)
4.7 (2.1)
6.1 (2.8)
1.2 (0.54)
1.9 (0.9)
3.2 (1.5)
4.4 (2)
Maximum
Load lb. (kgf)
Forcing Frequency in Cycles per Minute
Minimum Load for 81% Isolation lb. (kgf)
1000
3600
3000
2750
2500
2250
2000
1750
1500
Mode
3.0 (1.4)
.5 (0.2)
4.2 (1.9)
.8 (0.4)
7.7 (3.5)
1.5 (0.7)
10.4 (4.7)
2.2 (1)
1250
2.4 (1.1)
*
3.4 (1.5)
.7 (0.3)
6.3 (2.9)
1.3 (0.6)
8.5 (3.9)
1.8 (0.8)
NOTE: Dimensions in ( ) are mm.