| TYPICAL INSTALLATION ARRANGEMENTS
|
|||||
| Multiple Installations Any number of Finger-Flex mounts can be installed in parallel to achieve greater load-carrying capacity. These mounts may also be stacked in series to meet greater deflection requirements. Separators between mounts, if used, must be designed to meet the specific requirements of the installation. |
Typical Installations Finger-Flex mounts are used for office machines, electronic equipment, motors, air conditioning equipment, heating equipment, fans, blowers, pumps and scientific equipment. |
||||
| A. If the load support is 1/2 inch (12.7 mm) or more thick, two Finger-Flex bushings are generally used. |
![]() |
||||
| B. When the load supporting member is 1/8 inch (3.18 mm) to 1/2 inch (12.7 mm) thick, the standard bushing and ring combination is most suitable. |
![]() |
Rubber parts used are similiar to type V10R 4-1504 & V10R 4-1505 combination. The difference is that the flange of the rubber bushing within this assembled mounting has fingers on only one of its surfaces. The ring member absorbs both vibration and shock. |
|||
| C. If the load supporting member is less than 1/8 inch (3.18 mm) thick, the metal surrounding the mounting hole should be turned up. This provides additional mounting area for the bushing. |
![]() |
||||