CYLINDRICAL MOUNTS, NEOPRENE
to 16 lbs.
www.vibrationmounts.com • Phone: 516.328.3662 • FAX: 516.328.3365
|
|
| V100 page 1-24 |
|
 |
FASTENER:
Steel, Zinc Plated
ISOLATOR:
Neoprene
FOR COMPRESSION LOADS OF:
8 to 16 Pounds (3.6 to 7.3 kgf)
FOR SHEAR LOADS OF:
4.4 to 9 Pounds (2 to 4.1 kgf)
• OIL-RESISTANT ELASTOMER
|

NOTE: Dimensions in ( ) are in mm. |
| CAD |
Catalog
Number |
Mode |
Max.
Load
lb. (kgf) |
Forcing Frequency in Cycles per Minute |
1500 |
1750 |
2000 |
2250 |
2500 |
2750 |
3000 |
3600 |
|
|
| Minimum Load for 81% Isolation lb. (kgf) |
 |
V10Z 2-304A |
Compression |
8 (3.6) |
- |
- |
- |
- |
6.2 (2.8) |
4.8 (2.2) |
4.0 (1.8) |
3.2 (1.5) |
2.7 (1.2) |
2.0 (0.9) |
| Shear |
4.4 (2) |
4.0 (1.8) |
3.1 (1.4) |
2.2 (1) |
1.7 (0.8) |
1.3 (0.6) |
* |
* |
* |
* |
* |
 |
V10Z 2-304C |
Compression |
16 (7.3) |
- |
- |
- |
- |
- |
- |
14.0 (6.4) |
11.6 (5.3) |
9.6 (4.4) |
6.8 (3.1) |
| Shear |
9 (4.1) |
- |
9.0 (4.1) |
6.3 (2.9) |
4.6 (2.1) |
3.6 (1.6) |
2.9 (1.3) |
2.3 (1.04) |
1.9 (0.9) |
* |
* |
|
*At these forcing frequencies, lesser loads will yield less than 81% isolation.
CLICK CATALOG NUMBER TO CHECK PRICE AND AVAILABILITY. |
|
LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads. |
|
|
| |